This CAT5E Cable is the perfect fit for reliable installations where the cable will be used indoors. This cable's 8 conductors (4-Pairs) are solid bare copper with a high density polyethylene (HDPE) insulation and a PVC CM/CMR/CMP rated RoHS Compliant jacket. It's designed for indoor LAN applications, making it the ideal solution for indoor installation runs that require the cable to be installed in walls or any other non-plenum areas. This cable is also tested up to speeds of 350MHz.
VIEW DETAILS



ADSS Fiber Optic Cable
Adopted to the communication environment with high-voltage transmission network,lightning-prone areas and large span by the laying method of aerial.
PRODUCT DESCRIPTION
ADSS cable is loose tube stranded. Fibers, 125μm , are positioned into a loose tube made of high modulus plastics. The tubes are filled with a water-resistant filling compound. The tubes (and fillers) are stranded around a FRP (Fiber Reinforced Plastic) as a non-metallic central strength member into a compact and circular cable core. After the cable core is filled with filling compound. it is covered with thin PE (polyethylene) inner sheath. After stranded layer of aramid yarns are applied over the inner sheath as strength member, the cable is completed with PE or AT (anti-tracking) outer sheath.
Characteristics: | ||||||||
· Can be installed without shutting off the power | ||||||||
· Excellent AT performance, The maximum inductive at the operating point of AT sheath can reach | ||||||||
25kV | ||||||||
· Light weight and small diameter reducing the load caused by ice and wind and the load on towers | ||||||||
and backprops | ||||||||
· Large span lengths and the largest span is over 1000m | ||||||||
· Good performance of tensile strength and temperature | ||||||||
· The design life span is 30 years | ||||||||
Application: | ||||||||
The actual status of overhead power lines is taken into full consideration when ADSS cable is being designed. For overhead power lines under 110kV, PE outer sheath is applied. FOR power lines equal to or over 110kV, AT outer sheath is applied. The dedicate design of aramid quantity and stranding process can satisfy the demand on various spans. | ||||||||
Standards: | ||||||||
ADSS cable complies with Standard IEEE P 1222 as well as IEC 60794-1. | ||||||||
Storage/Operating Temperature : -40℃ to + 70℃ |
PARAMETER
Ref.outer diameter (mm) | Ref.weight (kg/km) | Ref.daily max.working tension (kN) | Max allowable working tension (kN) | Break strength (kN) | Strength member CSA | Modulus of elasticity kN/ mm2 | Heat expansion coefficient ×10-6 /k | |
12.5 | 125 | 136 | 1.5 | 4 | 10 | 4.6 | 7.6 | 1.8 |
13 | 132 | 142 | 2.25 | 6 | 15 | 7.6 | 8.3 | 1.5 |
13.3 | 137 | 148 | 3 | 8 | 20 | 10.35 | 9.45 | 1.3 |
13.6 | 145 | 156 | 3.6 | 10 | 24 | 13.8 | 10.8 | 1.2 |
13.8 | 147 | 159 | 4.5 | 12 | 30 | 14.3 | 11.8 | 1 |
14.5 | 164 | 177 | 5.4 | 15 | 36 | 18.4 | 13.6 | 0.9 |
14.9 | 171 | 185 | 6.75 | 18 | 45 | 22 | 16.4 | 0.6 |
15.1 | 179 | 193 | 7.95 | 22 | 53 | 26.4 | 18 | 0.3 |
15.5 | 190 | 204 | 9 | 26 | 60 | 32.2 | 19.1 | 0.1 |
15.6 | 194 | 208 | 10.5 | 28 | 70 | 33 | 19.6 | 0.1 |
16.3 | 211 | 226 | 12.75 | 34 | 85 | 40 | 20.1 | 0.1 |
16.8 | 226 | 242 | 15.45 | 41 | 103 | 48 | 24 | -0.4 |
17.2 | 236 | 253 | 16.2 | 45 | 108 | 51 | 25.1 | -0.5 |
17.9 | 249 | 266 | 18 | 50 | 120 | 58.8 | 26.1 | -0.8 |
Ref.outer diameter | (m) | |||
mm | Suitable span | |||
(NESC Standard,m) | ||||
A | B | C | D | |
12.5 | 160 | 100 | 140 | 100 |
13 | 230 | 150 | 200 | 150 |
13.3 | 300 | 200 | 290 | 200 |
13.6 | 370 | 250 | 350 | 250 |
13.8 | 420 | 280 | 400 | 280 |
14.5 | 480 | 320 | 460 | 320 |
14.9 | 570 | 380 | 550 | 380 |
15.1 | 670 | 460 | 650 | 460 |
15.5 | 750 | 530 | 750 | 510 |
15.6 | 800 | 560 | 800 | 560 |
16.3 | 880 | 650 | 880 | 650 |
16.8 | 1000 | 750 | 1000 | 760 |
17.2 | 1100 | 800 | 1100 | 830 |
17.9 | 1180 | 880 | 1180 | 900 |
RELATED PRODUCTS

Our CAT6 Bulk Ethernet Cable, Solid Copper UTP, 23 AWG 1000FT is an excellent choice. Supplied in a pull box, this 23 AWG cable is composed of four color striped twisted pairs (8 Conductors) made of solid copper. These conductors are surrounded by HD-PE insulation and Flame Retardant PVC/LSZH jacket that is RoHS Compliant, making it an ideal solution to installations in data room/ office/hotel, rated locations.
VIEW DETAILS
CAT6A Bulk Ethernet Cable, Solid 23AWG 1000FT 10G 500Mhz This cable comes in 6 color variations, supplied on a wooden spool. In addition, this network cable is manufactured with a low smoke generating FR-PVC jacket to resist sweltering and the spreading of toxic fumes in the case of a fire. The 23 AWG solid copper conductors are arranged into four color striped pairs to facilitate installation.
VIEW DETAILS